"As efficient and helpful as always! We have been loyal customers for over 20 years."
"Grant replaced our Rheem gas hot water heater and took the initiative to make pipework improvements."
"Even though fully booked found the time to repair the leak to prevent further water damage."
"Spent enough time making sure the whole drain was clean and not just the blockage site."
"Super reliable, professional, and always going the extra mile to keep our landlords and tenants happy."
"Prompt, professional and friendly service... fitting out my warehouse/workshop and toilet block."
Why Choose Northway
1946
Four Generations Since 1946
Northway has looked after Adelaide homes and businesses since 1946. Today, siblings Brett, Grant and Stacey Calladine carry on the family legacy: respect, trust and doing the job properly.
02
Same-Day Service
Most plumbing problems can’t wait, so we offer same-day service across Greater Adelaide. We turn up when we say we will, explain what we find and fix it properly.
03
Fixed Price, Up Front
You’ll know the price before we start, so there are no surprises on the invoice. Finance is available if you need it, and seniors get a discount on our standard pricing.
04
Lifetime Workmanship Guarantee
Every job is backed by a lifetime guarantee on our workmanship. That’s how a family business earns nearly 80 years of trust: no shortcuts, no compromises, and we stand behind our work.
05
24/7
24 Hour Emergency Service
Burst pipe, gas leak or no hot water? Our 24-hour emergency service covers Greater Adelaide. Our plumbers stay calm, make things safe and get you back up and running.
06
Licensed, Accredited and Trusted
We’re fully licensed for plumbing, gas fitting and electrical work (PGE 327229) and have been Master Plumbers SA members for 75 years. Councils, real estate agents and insurers trust us with their properties.

Continuous Gas Hot Water From Compact Gas Units Sized for Your Adelaide Household
A continuous hot water system heats water only as you use it, so there is no storage tank to run dry and no energy spent keeping stored water hot. Northway Plumbing, Aircon & Electrical supplies, installs, replaces and repairs continuous gas hot water systems across Adelaide, with fixed prices up front and a lifetime guarantee on workmanship.
Northway Plumbing, Aircon & Electrical has been looking after Adelaide homes since 1946. Four generations of our family have watched hot water move from big outdoor tanks to compact wall-mounted units, and we have installed and repaired them all. We supply, install, replace and repair continuous gas hot water systems across Adelaide, with same-day service where possible and a 24/7 emergency service when you are left without hot water.
What We Help With
Northway Plumbing, Aircon & Electrical helps Adelaide property owners with:
- Supply and installation of new continuous gas hot water systems
- Replacing storage tanks with continuous flow units
- Natural gas and LPG continuous flow installations
- Gas line checks and upgrades for continuous units
- Servicing, descaling and filter cleaning
- Repairs to ignition, sensors, flues and controls, including Rinnai, Rheem and Bosch units
- Emergency help when a continuous unit stops working
Northway has looked after Adelaide homes and businesses since 1946. Today, siblings Brett, Grant and Stacey Calladine carry on the family legacy: respect, trust and doing the job properly.
06
Rheem has supplied Australian homes since 1939. Our licensed Adelaide plumbers repair Rheem electric and gas storage, gas continuous flow, solar and AmbiPower heat pump systems, fixing leaks and trips.
Licensed, Accredited and Trusted
06
Licensed, Accredited and Trusted
Our licensed Adelaide plumbers service and repair Rinnai Infinity gas and Efinity electric continuous flow units, heat pumps, solar systems and storage tanks, including regular relief valve and anode checks.
Licensed, Accredited and Trusted
06
German-engineered Stiebel Eltron instantaneous and compact water heaters deliver hot water on demand. Our licensed Adelaide electricians and plumbers repair single and three-phase units, under-sink boilers and compact storage heaters.
06
Licensed, Accredited and Trusted
Made by Rheem, Vulcan electric and gas storage water heaters use high-strength steel, with spare parts available. Our licensed Adelaide plumbers diagnose and repair leaking, tripping or cold Vulcan systems.
Stiebel Eltron
German-engineered Stiebel Eltron instantaneous and compact water heaters deliver hot water on demand. Our licensed Adelaide electricians and plumbers repair single and three-phase units, under-sink boilers and compact storage heaters.
Commercial
Burst pipe, blocked sewer or overflowing toilet in the middle of the night? Our licensed Adelaide plumbers respond 24/7, find the fault fast and certify every job with the regulator.
Residential
Emergencies
Our licensed backflow plumbers install, test and commission backflow devices for Adelaide homes, businesses and growers, matching each to its hazard rating and reporting to the regulator within seven days.
Trade waste, grease arrestors and backflow protection for Adelaide businesses. Our commercial plumbers keep sites from Edinburgh Parks to Northern Adelaide Plains growers compliant with SA Water and regulator requirements.
Backflow Prevention
From leaking taps, toilets and showers, our licensed plumbers look after Adelaide homes, with every job certified to the Technical Regulator and covered by SA’s 10-year defective work warranty.
The City of Mitcham has trusted Northway with public projects including toilet facilities at CC Hood Reserve and Hillview Reserve, the Hawthorn Community Centre kitchen, and recent pipe relining at the Mitcham Civic Centre.
Trusted by Local Councils
Meet Brett and Grant Calladine, Owners of Northway
Brett and Grant Calladine are the fourth generation of the Northway family. Their great-grandfather, Ernest John Northway, started the business in Adelaide in 1946. Today, the two brothers run it as Directors, with their sister Stacey managing the office. Brett leads the business as General Manager, and in 2019 he was named Certified Trade Professional of the Year at the Master Builders SA Building Excellence Awards. Grant runs day-to-day operations and is often the one who comes out to quote, making sure every job is done properly from start to finish.
Together, they lead a team of experienced licensed plumbers and apprentices, keeping alive the family values Ern started with: respect, trust and honest workmanship. When you call Northway, you’re dealing with a family business that has stood behind its work for nearly 80 years.
Accreditations & Licences
We hold the licences and industry accreditations that matter for Plumbing, Electrical and Air Conditioning in Adelaide, so every job we do is fully compliant and backed by recognised industry bodies.
Awards, Recognition and Media
For nearly 80 years, Northway has built its reputation one job at a time. Along the way, our team and our work have been recognised by South Australia’s leading industry bodies, local councils and the customers we look after every day.
Certified Trade Professional of the Year
Director Brett Calladine was named Certified Trade Professional of the Year at the 2019 Master Builders SA Building Excellence Awards. The award recognises the highest standards of skill, professionalism and workmanship in South Australian trades.
Master Plumbers SA Member of the Month
Northway was named Member of the Month by Master Plumbers SA and featured in a two-page spread in the association’s newsletter. In it, Gill, Brett and Grant shared their insights on the plumbing industry.
75 Years with Master Plumbers SA
In 2025, Grant and Brett received a commemorative certificate at the Master Plumbers SA President’s Luncheon, marking 75 years of membership. Northway is one of the association’s longest-standing member businesses.
Trusted by Local Councils
The City of Mitcham has trusted Northway with public projects including toilet facilities at CC Hood Reserve and Hillview Reserve, the Hawthorn Community Centre kitchen, and recent pipe relining at the Mitcham Civic Centre.

Workmanship Guarantees & Product Warranties
Every job Northway completes comes with a lifetime guarantee on our workmanship. If something we’ve done isn’t right, we’ll come back and fix it. We combine old-school service values with modern techniques and cutting-edge equipment, from thermal imaging leak detection to CCTV drain cameras and pipe relining, so problems are found accurately and fixed properly the first time.
We use quality, approved materials from trusted Australian suppliers, and the hot water systems, tapware, fixtures and parts we install carry their manufacturer’s warranty too. Our family has stood behind its work since 1946, and that hasn’t changed.
No shortcuts. No compromises. Just work you can rely on.
Continuous Hot Water System Rules and Regulations in Adelaide
Most continuous flow systems in Adelaide run on natural gas or LPG, so two sets of rules apply. Under South Australia’s water heater requirements, a gas continuous flow unit must generally be rated at 5 stars or more. It must also be a Type A appliance certified by a recognised body such as AGA before it can be sold or installed in the state. The gas side must be installed by a gas fitter registered with Consumer and Business Services. It must meet AS/NZS 5601.1:2022 under the Gas Act 1997 and Gas Regulations 2012, and the fitter must issue a gas electronic Certificate of Compliance (eCoC). The water side must meet AS/NZS 3500.4 and the Plumbing Code of Australia (NCC Volume Three). New installations generally cap bathroom outlets at 50°C. A plumbing eCoC must reach you and the Office of the Technical Regulator within seven days. Flue clearances from windows, doors and boundaries are set by the gas standard, so placement on your wall matters. Ask for both certificates, and check the unit’s star rating and certification label before you sign off the job.
Emergency work still gets certified. A plumber must lodge an electronic Certificate of Compliance with the Office of the Technical Regulator within 7 days. Their CBS licence number must appear on all advertising.
Continuous Hot Water Facts in Adelaide
Five stars is the benchmark. Under SA’s water heater rules, gas continuous-flow units rated 5 stars or more count as low-emission. They can be installed in new and existing homes.
There’s one 3-star exception.A 3-star gas continuous-flow unit can go in an enclosed space in an existing home, but not where development approval is needed.
Electric instantaneous is allowed in some cases. Electric instantaneous units of up to 15 kW with no more than 1 L of storage are permitted. Whether one is allowed depends on the building and whether mains gas is available.
Mains gas is widely available.Australian Gas Networks supplies 486,973 SA customers through 8,510 km of mains. About 34,000 more connections are forecast between 2026–27 and 2030–31.
Gas prices are rising. SA residential gas standing offers rose 4.8% in the year to 30 June 2026. Households on standing offers could save 410 a year by switching to their retailer’s best market offer.
Gas work must be certified. Installing or moving a gas appliance requires an electronic Certificate of Compliance from a licensed gas fitter. Penalties reach $5,000.
Adelaide Continuous Hot Water Local Snapshot
The rules and running costs behind continuous-flow hot water in Adelaide.
Minimum gas rating
5 stars
Low-emission standard, SA
Electric instantaneous limit
15 kW, ≤ 1 L
Where electric is allowed
SA gas customers
486,973
AGN network, 2024
Median gas bill
$1,123
SA residential, 2024–25
Standing offer rise
+4.8%
Year to 30 June 2026
Saving by switching plans
410/yr
Standing to best market offer

Continuous Hot Water System Cost in Adelaide
A continuous flow gas hot water system in Adelaide typically costs $1,375 to $3,200+ supplied and installed, with most installations around $2,000. Where the price falls depends on the unit’s flow rate in litres per minute, the brand, and whether the gas line or flue needs upgrading to handle the higher gas demand. Switching from a storage tank to continuous flow can also involve moving the unit or adding temperature controllers, which adds to the cost.
Because continuous flow systems heat water only when a tap is turned on, there is no tank losing heat overnight. They are also compact enough to mount on an outside wall, which suits smaller Adelaide homes and units. Northway sizes the unit to the number of bathrooms and outlets you run at the same time, so the shower stays hot even when the dishwasher is going.
Understanding Continuous Gas Hot Water Systems
A continuous gas hot water system heats cold water on demand as it flows through the unit, rather than keeping a large volume of stored water hot around the clock. There is no tank to corrode, no standby heat loss and no waiting for a cylinder to reheat after a long shower. Northway Plumbing, Aircon & Electrical installs these units across Adelaide because they solve the two complaints we hear most about old tanks: running out, and taking up space.
You may hear them called continuous flow, instantaneous or tankless systems. They all work on the same principle: water is heated as it passes through a heat exchanger, and the burner switches off when you close the tap. In Adelaide’s mix of older detached homes, infill townhouses and new builds, they have become a practical favourite where space is tight and several taps need hot water at once.
What “Continuous Flow” Really Means
Continuous flow means hot water keeps coming for as long as the tap is open, within the unit’s rated capacity. Because the unit stores no water, there is no large cylinder in the yard or laundry and no tank lining to rust through.
A continuous gas unit has four main parts:
- A gas burner, fuelled by natural gas or LPG
- A heat exchanger that transfers heat into the passing water
- Electronic sensors and controls that manage temperature
- A compact casing, usually mounted on an external wall
Most Adelaide homes with a natural gas connection can accommodate one of these units on a side wall or in a courtyard. Where mains gas is not available, LPG models are a common alternative.


How Continuous Gas Hot Water Systems Work In Practice
A continuous gas system follows the same sequence every time you use hot water:
- You open a hot tap or start an appliance that uses hot water.
- A flow sensor detects water moving through the unit. A minimum flow is needed before the burner will start.
- The burner ignites and the heat exchanger warms the water as it passes through.
- Temperature sensors adjust the flame to keep the outlet temperature steady.
- When you close the tap, the burner shuts off and gas use stops.
Many units let you set the delivery temperature on the unit or with a wall controller, and a tempering valve or built-in temperature limit keeps bathroom outlets at a safe temperature. That matters most in homes with young children or older residents. With correct sizing, a continuous system can handle morning showers across more than one bathroom, a load of washing and the kitchen without the temperature swings common to tired, undersized tanks.
Major Leaks Under Sinks, Basins and Appliances
Roof, Gutter and Storm-Related Plumbing Emergencies
Flexible hoses under kitchen sinks and vanities, dishwasher connections and basin wastes are common failure points, and they can fail without warning. A leak that starts overnight or while you are away can swell cupboard bases and damage flooring.
When you call, we can talk you through closing the isolation valve or turning off the appliance. We then replace the failed hoses, valves or pipework and check for other hidden leaks.
Heavy Adelaide downpours test gutters, downpipes and stormwater drainage. Blocked downpipes, overflowing gutters and failed flashings can send water through ceilings and into insulation.
In a storm, we focus on making things safe: clearing blocked downpipes and drains and restoring drainage flow. Once conditions allow, follow-up repairs can be arranged through our leaking roof repairs and blocked stormwater drain teams.
Choosing A Continuous Hot Water System In Adelaide
Choosing a continuous hot water system in Adelaide comes down to whether your property suits one, and then choosing a unit with enough capacity for the way you use hot water. Northway Plumbing, Aircon & Electrical assesses both on site.
Sizing Your Continuous Hot Water System For Adelaide Conditions
Continuous flow units are sized by flow rate, meaning how many litres of hot water per minute they can deliver, rather than by tank volume. The right size depends on how many hot water outlets you have and how many are likely to run at once. A one-bathroom unit for a couple needs far less capacity than a family home with several bathrooms, a bath and an outdoor kitchen.
Adelaide’s seasons matter here. Winter mains water is much colder, so the unit has to raise the temperature further, and it delivers less hot water at a time than it does in summer. A unit that copes easily in January can struggle on a July morning if it was sized too tightly.
Our plumbers size units on site rather than guessing. We count fixtures, consider simultaneous use, measure pipe runs and check that your gas supply can deliver what the unit needs. Oversizing wastes money on the unit; undersizing leads to temperature drops when more than one tap is open.
Is Continuous Gas Hot Water Right For Your Property?
Continuous gas suits a wide range of Adelaide properties, including family homes with two or more bathrooms, investment units, townhouses with limited outdoor space, and small premises such as cafés and offices.
Ask yourself:
- Does the property have natural gas, or could it use LPG?
- Is the current system an ageing, leaking or undersized tank?
- How many bathrooms, kitchens and laundries use hot water, and at the same time?
- Is there external wall space for a compact unit?
- How is the water pressure at the property?
A continuous gas system is generally a strong fit when:
- The property has a reliable gas supply with an adequately sized gas line
- Several outlets need hot water at overlapping times
- Freeing up yard or laundry space matters
- The household wants to stop paying to keep a tank of water hot all day
Another system type may suit better when:
- There is no gas connection and adding one is impractical
- Hot water use is very low, such as a single occupant
- The owner specifically wants an all-electric option such as a heat pump
Indoor vs Outdoor Units And Placement Around Adelaide Homes
Most continuous gas units in Adelaide are outdoor wall-mounted models. They avoid the flueing and ventilation work an indoor unit needs, which keeps installation simpler. Side walls, courtyards and rear walls common in Adelaide housing usually suit them well.
Indoor units are an option for some apartments and properties without a suitable external wall, but they need compliant flueing, adequate ventilation and careful attention to building requirements, which adds cost and complexity.
When choosing a position, we consider:
- Keeping the unit reasonably close to bathrooms and the kitchen, so hot water arrives sooner
- Clearances around the unit for servicing and compliance
- The size and length of the gas line from the meter
We regularly work in older Adelaide suburbs where side paths are narrow and courtyards are tight, and we know how to fit a unit neatly while meeting every requirement.
07
Handover. We explain how to use the unit and provide documentation for our lifetime guarantee on workmanship and the manufacturer’s warranty.
Our Step-by-Step Process For Continuous Hot Water Installation
Whether you are building, renovating or replacing an old tank, our process is designed to be clear and calm:
01
Call us on (08) 7282 0809 to talk through the property, your current system and your timing.
02
On-site assessment. A licensed technician checks your gas supply, pipework, hot water demand, existing system location and suitable mounting positions.
03
Recommendation and fixed price. We recommend a capacity and position, discuss suitable brands, and give you a fixed price up front.
04
Removal of the old system. We safely disconnect and remove the old tank or unit.
05
Installation. We complete the gas and water connections and all compliance checks.
06
Commissioning and testing. We set the temperature, check flow at each fixture and confirm the safety controls work.
07
Handover. We explain how to use the unit and provide documentation for our lifetime guarantee on workmanship and the manufacturer’s warranty.
Common Continuous Hot Water Problems In Adelaide And How We Fix Them
Even well-installed continuous systems develop faults over time. Adelaide’s mineral-rich water, older pipework and busy households all contribute to wear. Early attention usually means a simpler fix.
No Hot Water At All
Symptoms: only cold water at every hot tap, and the unit is not igniting or appears dead.
Before calling, check:
- Is the gas meter valve open, and do your other gas appliances work?
- Does the unit have power? Most continuous units need a small electrical supply for ignition and controls.
- Is an error code showing on the unit or controller?
If those checks do not solve it, call Northway on (08) 7282 0809. Our 24/7 emergency service attends no-hot-water calls across Adelaide.
Intermittent Or Fluctuating Water Temperature
Symptoms: water swinging hot and cold mid-shower, especially when another tap or appliance turns on.
Typical causes include:
- A unit too small for simultaneous demand
- Incorrect gas pressure or an undersized gas line
- Blocked filters or inlet strainers
- Failing temperature sensors
We measure flow, check gas pressure against the manufacturer’s specifications, inspect filters and sensors, and test the unit under load. Cleaning, adjustment or a replacement part usually restores steady temperature.
Low Hot Water Pressure Or Error Codes
Scale from mineral-rich water, debris in inlet filters or pressure-limiting valve problems can all reduce flow. If flow drops below the minimum the unit needs, the burner may not fire at all.
Most modern units display fault codes that point to issues such as flue blockages, ignition failures, flame detection problems or overheating. Our team reads these codes and carries out the right repair. Please do not open or repair a gas appliance yourself; all gas work must be done by a licensed gas fitter.
What Customers Say About Our Hot Water Installations
Andy H.
"Friendly and professional, highly recommended! Grant replaced our Rheem gas hot water heater and took the initiative to make pipework improvements and explain the benefits."
Jim W.
"Starting from the beginning at providing a quote, to answering questions relating to the quote and then arranging time to do the installation and following up with explanations about the appliance, they have achieved 5 out of 5 performance."
Ratna S.
"Fast & friendly team, shout-out to Brett that solved our hot water issues effectively & efficiently. Job well done, thank-you!"
Lisa N.
"Northway are so easy to deal with and Craig got our hot water back to hot easily."
Continuous Hot Water Across Adelaide
We service all suburbs of Adelaide. Continuous gas units are a popular choice for townhouses in Mawson Lakes and Bowden, character homes with narrow side paths in Unley and Kensington, family homes in Golden Grove and Modbury, beachside properties in Henley Beach and Brighton where a compact unit is easier to protect from salt air, and Hills homes around Stirling where LPG is often the gas supply.
Next Steps
A continuous hot water system is a reliable, space-saving choice for many Adelaide properties when it is sized correctly and installed by experienced professionals. It delivers hot water on demand without the bulk, corrosion risk and standby losses of a storage tank.
Here is what to do next:
- No hot water right now? Call Northway on (08) 7282 0809 for our 24/7 emergency service.
- Thinking about switching from a tank? Book a site visit and we will assess your gas supply, space and hot water use.
- Existing unit showing error codes or fluctuating? Ask us for an inspection and repair.
- Landlord or property manager? Talk to us about dependable continuous flow options for tenanted properties.
Call Northway Plumbing, Aircon & Electrical on (08) 7282 0809 or contact us online to talk about a continuous hot water system for your Adelaide property.
FAQs about Continuous Hot Water Systems in Adelaide
Does a continuous hot water system ever run out of hot water?
A correctly sized continuous gas system does not run out the way a storage tank does, because it heats water as it flows. It will, however, deliver less hot water at once if too many outlets run together or the unit is undersized, especially in winter when mains water is colder. Northway sizes each unit on site to match how many outlets you use at the same time.Can I replace my storage tank with a continuous gas unit?
Yes, and it is one of the most common hot water upgrades in Adelaide. The changeover may need a larger gas line, rerouted pipework and a new mounting position, and an electric tank will need a gas or LPG supply. Northway assesses all of this at the site visit and gives you a fixed price up front before any work begins.Will a continuous hot water system work if the power goes out?
Usually not. Most continuous gas units need a small electrical supply to run the ignition, sensors and controls, so they stop when the power is out, even though the gas is still on. A gas storage tank may still hold some hot water during a short outage. We can explain how your specific unit behaves during supply interruptions.Can a continuous gas system run on LPG in Adelaide?
Yes. Continuous flow units are available for both natural gas and LPG, which makes them an option for Adelaide Hills and fringe properties without mains gas. The unit must be the correct version for the gas type and installed by a licensed gas fitter. Northway checks your gas supply and LPG setup as part of the assessment.How often should a continuous gas hot water system be serviced?
Servicing frequency depends on the unit, how heavily it is used and local water conditions, and the manufacturer’s guidance is the best starting point. In Adelaide, mineral-rich water gradually builds scale in the heat exchanger, so regular checks of filters, burner, flue, gas pressure and scale help protect efficiency. Northway can book a service and advise on a sensible interval for your unit.